ContaminationSensor CS 1000 Operating the CS1x2x using the keypad
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 40/112
BeWa CS1000 3764916 300 en-us 2012-08-29.doc 2012-08-29
Measuring Menu (CS12xx)
During measurement operation, you can perform the following settings:
Selection To do
Start the measuring menu
Press the
o.k.
key.
Exit the measuring menu without
saving
Scroll through to CANCEL and press the
o.k.
-key.
If a key is not pressed within 30 seconds, the
system jumps back automatically.
Save and exit the measuring menu
Scroll through to SAVE and press the
o.k.
-
key.
Measuring menu:
Code
DSPLAY
Set display
SWtOUT
Configure switching output
ANaOUT
Set analog output - output
signal
CANCEL
Discard changes and exit
SAVE
Save changes and exit
DSPLAY - Display after sensor is switched on
DSPLAY
Set start display
+
Code
ISO
3-digit ISO code
SAE A
SAE class A
SAE B
SAE class B
SAE C
SAE class C
SAE D
SAE class D
SAeMAX
SAE A-D
FLOW
Flow rate range
ANaOUT
Analog output in mA
DRIVE
LED current in %
TEMP C
Fluid temperature in °C
TEMP F
Fluid temperature in °F