Connect Systems CS1000 Spécifications Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 112
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
ContaminationSensor CS 1000 Reading the analog output
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 59/112
BeWa CS1000 3764916 300 en-us 2012-08-29.doc 2012-08-29
SAE + T
The SAE+T signal consists of 5 measured values which are transmitted time-coded
with the following time slices:
4,0 2,0
I (mA)
1
2
4
6
8
10
3
5
7
9
U (V)
time (ms)
4,8
19,2
High
High
Low
Low
300
3000
3000
3000
3000
2,25
2,4
9,6
4,5
9,7519,5
9,9
10,0
9,85
19,7
0,0
19,8
_
Time
Signal Size Signal
duration
per pulse
in ms
Current (I) / Voltage (U)
1 Identifier SAE A 300 High / Low
2 Measured
value
SAE A 3000
Current/Voltage for measured value
3 Identifier SAE B 300 High / Low / High / Low
4 Measured
value
SAE B 3000
Current/Voltage for measured value
5 Identifier SAE C 300 High / Low / High / Low / High / Low
6 Measured
value
SAE C 3000
Current/Voltage for measured value
7 Identifier SAE D 300 High / Low / High / Low / High / Low / High / Low
8 Measured
value
SAE D 3000
Current/Voltage for measured value
9 Identifier Temperature 300 High / Low / High / Low / High / Low / High / Low /
High / Low
10 Measured
value
Temperature 3000
Current/Voltage for measured value
Vue de la page 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 111 112

Commentaires sur ces manuels

Pas de commentaire